9.3. Setpoint Comparison
This function includes the weighing sequence and uses for getting preset target
weight.
There are four parameters of "Final", "Preliminary", "Free fall" and "Zero band" to
use the setpoint comparison.
The result of the sequence is output to three relays.
When inputting these parameters, it is not necessary to input the F-function f-^0
again unless changing the F-function.
Caution □ This function is normal batching only and can not perform loss-in-
weight.
9.3.1. Selecting Setpoint Comparison
step 1 Press the lOperaTe/Standbyl key to turn display off.
Press and hold the [MOPEl key and press the
Operaie/Standbvi key to enter the F-function mode.
Step 2 Select f-c’O c’ (setpointcomparison).
F-FunctiorLmode
Comparator function
/
Setpoirit comparison /
Step 3 Turn the display off using the [Operate/Standbyl key.
Display off
9.3.2. Description of Input parameters and Outputs
Weighing value a
SETO, Final
SET2, Preliminary
Tared Zero
Caribrated Zero
Preset target weight
Weighing trace
Relay HI, Net ^ {Final - Free fall)
OFF (Break)
ON (Make)
OFF (Break)
Relay OK, Net^ (Final - Preliminary)
OFF (Break) | ON (Make) OFF (Break)
Relay LO, Gross < Zero band
ON (Make) OFF (Break)
ON (Make)
Parameters List
SETO Final
Set a preset target weight.
SETI Free fall Set a corrective value related to closing the dribble flow gate.
SET2 Preliminary
Set a begining point to use the dribble flow gate on!y.
SETS
Zero band
Set a value to regard as neariy zero.
AD-4329 Weighing Indicator
Page 39
9,3. Setpoint Comparison